EPSON Stylus Pro 7000 Revision B
Adjustment Self-Diagnostic Mode Menus 192
TEST PATTERN PRINT
This function prints a test pattern plus certain printer information/settings that
you can refer to when performing printer adjustment procedures. For a list of
the information that is printed, see the following table.
To print the list of variable items you need to enter the printer’s serial number
when prompted. The serial number is located on the back of the printer, next
to the power connector.
Figure 5-39. Test Pattern Printing Operation
Table 5-13. Printed Items in the Test Pattern
Item Description
Nozzle Check
Prints all of the check/test patterns that are available
from the "Adjustment" menu.
Adjustment Variables
Prints a list of all the adjustable items from the
"Adjustment" menu.
Print: Nozzle Check
[Enter]
[Enter]
[SelecType]/
[Item]
[SelecType]/
[Item]
The printer prints the adjustment-
parameter list, ejects the paper, and
proceeds to next menu.
End
adjustment/
next menu
Printing Pattern
Printing Pattern
Print: Adj. Variable
No. X: PEG
* * * * * * *
Print Adj. Pattern
Paper Feed [+] or [-]
X = "1"~"4"
*
= Serial number