3. To Clear a Single Crosspoint Key Memory:
Hold a key bus crosspoint, single press CLEAR WORK
BUFR button:
Clears only the key memory portion of the Current Working
Buffer for switcher key crosspoints held down. Clears any
split keys for that key crosspoint.
4. To Clear Current Working Buffer for a selected E-MEM level
and clear any split keys for that key crosspoint— including
Keyers for E-MEM level owning Crosspoint Keyer:
Hold a key bus crosspoint, double press the CLEAR
WORK BUFR button.
CLEAR WORK BUFR is always functional, even when the other
effects editing buttons are not enabled (KEYFRAME EDITING set to
DISABLE
in the Keyframe Menu).
The CLEAR WORK BUFR button is normally off, but lights for
one-half second when pressed.
NOTE:
The “Current Register” is defined as the active register on each
E-MEM level. If all enabled levels are in the same register, the Current
Register is the same as that shown in the E-MEM keypad display.
However, if the enabled levels have different Current Registers, as
indicated by a “
” between the bank number and the register number,
the Get and Put operations will operate on different registers. For
example, if enabled level M/E 1 is in Register 1, and enabled level M/E 2
is in Register 2, a “PUT CUR INTO 03” operation will copy M/E 1
Register 1 into M/E 1 Register 3, and M/E 2 Register 2 into M/E 2
Register 3.
GET provides a method of copying or “getting” the contents of a
specified register into the current register.
The current switcher state and the current register number are
unaffected.
Get