Polycom (RMX) 1500 Security Camera User Manual


  Open as PDF
of 1183
 
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide
Polycom®, Inc. 747
4 In the New Value field, enter the flag’s new value.
5 Click OK to close the Update Flag dialog box.
6 Repeat steps 2–4 to modify additional flags.
7 Click OK to close the System Flags dialog box.
MCMS_PARAMETERS_USER Flags
For flag changes (including deletion) to take effect, reset the MCU. For more information see
Resetting the Collaboration Server.
Flag Description
ALLOW_NON_ENCRYPT_
PARTY_IN_ENCRYPT_CONF
If YES, allows non-encrypted participants to connect to encrypted
conferences.
Default: NO
Note: From Version 7.6.1, this flag is replaced by the Encryption
option Encrypt when Possible in the conference Profile - Advanced
dialog box. Flag setting is ignored.
ALLOW_NON_ENCRYPT_
RECORDING_LINK_IN_
ENCRYPT_CONF
When set to NO (default), the Recording Link inherits the encryption
settings of the conference. If the conference is encrypted, the
recording link will be encrypted.
When set to YES, it disables the encryption of the recording link,
regardless of the Encryption settings of the conference and RSS
recorder.
AUTHENTICATE_USER This flag is not supported from Version 7.7.
If the external database application is to be used to verify that
operators are authorized to log in to the MCU, set the value of this flag
to YES.
If the value of this flag is set to NO, the MCU database is used to verify
that operators are authorized to log in to the MCU.
Note: If the flag is set to YES, the flow is first to look in the internal DB
and then go out to the external one.
Flags for SE200 need to be added manually.