RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide
Polycom®, Inc. 821
A system reset does not reset the Login attempts counter.
The time period during which the three consecutive Login failures occur is determined by the value of the
USER_LOCKOUT_WINDOW_IN_MINUTES System Flag. A flag value of 0 means that three consecutive
Login failures in any time period will result in User Lockout. Value can be between 0 and 45000.
The duration of the Lockout of the user is determined by the value of the
USER_LOCKOUT_DURATION_IN_MINUTES System Flag. A flag value of 0 means permanent User
Lockout until the administrator re-enables the user within the system. Value can be between 0 and 480.
User Login Record
The system can display a record of the last Login of the user. It is displayed in the Main Screen of the
Collaboration Server Web Client or Collaboration Server Manager. The user Login Record display is
enabled when the LAST_LOGIN_ATTEMPTS System Flag is set to YES.
Both lists display the:
● Date and Time of the Login attempt.
● IP Address of the workstation initiating the Login attempt.
The list of unsuccessful Logins can contain up to ten records.
Failed Login attempts are written to the system Log Files and are recorded as Audit Events. The Audit
files can be retrieved by the Administrator User.
Controlling User Sessions
Management Sessions per System
It is possible for a several users to simultaneously log in to the Collaboration Server and initiate
management sessions from different instances of the Collaboration Server Web Client or Collaboration
Server Manager that are running on a single or several workstations.
The maximum number of concurrent management sessions (http and https connections) per system is
determined by the value of the MAX_NUMBER_OF_MANAGEMENT_SESSIONS_PER_SYSTEM
System Flag.