IBM AS/400 Photo Scanner User Manual


 
Press Enter, the F3, or F12 key after you specify the parameters, or press the F4
key to specify more parameters.
By pressing the F4 key, the following display appears. You can enter the page
segment name in the following display and complete the operation, or obtain the list
of page segments by pressing the F4 key in the Page segment field.
Note: The Overlay Utility and the Print Format Utility do not verify whether the
page segment you specified exists in the resource library or not because the page
segment does not need to exist at this time. See “Page Segment” on page 389
and “Page Segment” on page 392 for more information.
Field Name Description
Control You may move the image area window by entering one of the following
commands in this field and pressing Enter:
-n Backward
The image area moves n lines toward the top line of the
overlay, the record layout, or the page layout.
+n Forward
The image area moves n lines toward the bottom line of the
overlay, the record layout, or the page layout.
W-n Left
The image area moves n columns toward the first column of
the overlay, the record layout, or the page layout.
W+n Right
The image area moves n columns toward the last column of
the overlay, the record layout, or the page layout.
n The image area moves to the nth line.
Wn The image area moves to the nth column.
*TOP The image area moves to the top line.
*BOT The image area moves to the bottom line.
| When designing an overlay, a simulated printout of the overlay can be
| displayed on the workstation. See the Control field Help for further
| information and restrictions.
| *VIEW A simulated printout of the overlay will be displayed. This
| function is not available when designing record layouts and
| page layouts.
Mark The element mark is displayed in this field. It could be either a
system-assigned mark or a user-assigned name.
Measurement
method
This field shows the measurement method used to specify the position.
You may change this field by pressing the F6 key.
Position The position parameter consists of across and down values. These
values specify the horizontal and vertical position of the element being
defined.
Page Segment You need to enter the name of the desired page segment. Then press
Enter to complete the place page segment operation.
Chapter 13. Design Operation 265