IBM AS/400 Photo Scanner User Manual


 
By pressing the F4 key, one of the following displays appears. You can enter the
data in the following display and complete the operation, or obtain the list of the
folders, the PC documents, the files, the libraries, or members by pressing the F4
key in each field.
Note: The Overlay Utility and the Print Format Utility do not verify whether the
name you specified exists in the resource library or not because the graphics does
not need to exist at this time. It will be checked when an overlay is created or a
database file is printed with the PFD definition. When you specify '1=PC
Document' as the source object type, then press F4, the following display appears:
Place Graphics Detail
Mark: ᑍG3 Measurement method: Row/Column
Type choices, press Enter.
Start position:
Across . . . . . . . . . . 1 1-999
Down . . . . . . . . . . . 4 1-999
End position:
Across . . . . . . . . . . 41 1-999
Down . . . . . . . . . . . 14 1-999
Source object type . . . . . 1 1=PC document, 2=File
Folder . . . . . . . . . . .
Name
PC document . . . . . . . . Name, F4 for list
Element . . . . . . . . . . Name
Degree of rotation . . . . . , 9, 18, 27
Font . . . . . . . . . . . . ᑍDEFAULT ᑍDEFAULT, 1-8, F4 for list
Bottom
F3=Exit F4=Prompt F5=Refresh F6=Change measurement method F12=Cancel
When you specify '2=File' as the source object type, the following display appears:
Place Graphics Detail
Mark: ᑍG3 Measurement method: Row/Column
Type choices, press Enter.
Start position:
Across . . . . . . . . . . 1 1-999
Down . . . . . . . . . . . 4 1-999
End position:
Across . . . . . . . . . . 41 1-999
Down . . . . . . . . . . . 14 1-999
Source object type . . . . . 2 1=PC document, 2=File
File . . . . . . . . . . . . Name, F4 for list
Library . . . . . . . . . ᑍLIBL Name, ᑍLIBL, ᑍCURLIB
Member . . . . . . . . . . . ᑍFIRST Name, ᑍFIRST, F4 for list
Element . . . . . . . . . . Name
Degree of rotation . . . . . , 9, 18, 27
Font . . . . . . . . . . . . ᑍDEFAULT ᑍDEFAULT, 1-8, F4 for list
Bottom
F3=Exit F4=Prompt F5=Refresh F6=Change measurement method F12=Cancel
The following table explains each field in these displays.
272 AFP Utilities for AS/400 User’s Guide