12−12
12.18 Power Management Capabilities Register
The power management capabilities register indicates the capabilities of the SD host controller related to PCI power
management. See Table 12−13 for a complete description of the register contents.
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Name Power management capabilities
Type RU R R R R R R R R R R R R R R R
Default 0 1 1 1 1 1 1 0 0 0 0 0 0 0 1 0
Register: Power management capabilities
Offset: 82h
Type: Read/Update, Read-only
Default: 7E02h
Table 12−13. Power Management Capabilities Register Description
BIT FIELD NAME TYPE DESCRIPTION
15 PME_D3COLD RU PME support from D3
cold
. This bit can be set to 1 or cleared to 0 via bit 4 (D3_COLD) in the general
control register at offset 88h in the PCI configuration space (see Section 12.22). When this bit is set
to 1, it indicates that the SD host controller is capable of generating a PME
wake event from D3
cold
.
This bit state is dependent upon the SD host controller V
AUX
implementation and may be configured
by using bit 4 (D3_COLD) in the general control register (see Section 12.22).
14−11 PME_SUPPORT R PME support. This 4-bit field indicates the power states from which the SD host controller may assert
PME
. This field returns a value of 1111b by default, indicating that PME may be asserted from
the D3
hot
, D2, D1, and D0 power states.
10 D2_SUPPORT R D2 support. Bit 10 is hardwired to 1, indicating that the SD host controller supports the D2 power state.
9 D1_SUPPORT R D1 support. Bit 9 is hardwired to 1, indicating that the SD host controller supports the D1 power state.
8−6 AUX_CURRENT R 3.3-V
AUX
auxiliary current requirements. This requirement is design dependent.
5 DSI R Device-specific initialization. This bit returns 0 when read, indicating that the SD host controller does
not require special initialization beyond the standard PCI configuration header before a generic class
driver is able to use it.
4 RSVD R Reserved. Bit 4 returns 0 when read.
3 PME_CLK R PME clock. This bit returns 0 when read, indicating that the PCI clock is not required for the SD host
controller to generate PME
.
2−0 PM_VERSION R Power-management version. This field returns 010b when read, indicating that the SD host controller
is compatible with the registers described in the PCI Bus Power Management Interface Specification
(Revision 1.1).