Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Management Terminal and Activate System
Page 3-3Install Management Terminal
3
Unpack and Inspect
1. Unpack the terminal and inspect for damage. Report all damage
according to local requirements.
2. Remove and retain the installation and usage instructions from the carton.
These instructions are needed to set up the terminal after it is installed.
3. Set the terminal, keyboard, and all cables onto the equipment room table.
Install a 715 BCS Terminal
1. Plug the keyboard cable into the 6-pin mini-DIN jack on the rear of the
terminal. See Callout 2 in Figure 3-2 on page 3-4
.
2. Plug the supplied 25-pin Data Terminal Equipment (DTE) cable into the P2
port (center connector) on the rear of the terminal.
Install a 2900/715 BCS Terminal
1. Plug the keyboard cable into the 6-pin RJ-11 jack on the left side of the
terminal. An adapter cable is available to convert a 6-pin mini DIN jack to
an RJ-11 jack to allow a 715 BCS keyboard to be used (comcode
847489895 or 847489903).
2. Plug the supplied 25-pin Data Terminal Equipment (DTE) cable into the P2
port (right side connector). See Callout 4 in Figure 3-2 on page 3-4
.
Install a 715 BCS-2 Terminal
1. Plug the keyboard cable into the modular keyboard jack on the rear of the
terminal. See Callout 5 in Figure 3-2
. This is a unique cable and must be
connected to the 715 BCS-2 only.
2. Plug the supplied 25-pin Data Terminal Equipment (DTE) cable
(H600-426) into the COM1 port (right side connector).