Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Option Switch Settings
Page B-10TN760D Tie Trunk Option Settings
B
TN760D Tie Trunk Option Settings
The TN760D Tie Trunk circuit pack interfaces between four tie trunks and the
TDM bus. Two tip and ring pairs form a 4-wire analog transmission line. An E and
M pair are DC signaling leads used for call setup. The E-lead receives signals
from the tie trunk and the M-lead transmits signals to the tie trunk.
To choose the preferred signaling format (Tab le B -5
and Tab le B -6 ), set the
switches on the TN760D and administer the port using Figure B-2
and Ta b le B- 7 .
1. An open circuit is preferred instead of battery voltage.
Table B-5. Signaling Formats for TN760D
Mode Type
E & M Type I Standard (unprotected)
E & M Type I Compatible (unprotected)
Protected Type I Compatible, Type I Standard
Simplex Type V
E & M Type V
E & M Type V Revised
Table B-6. Signaling Type Summary
Signaling Type Transmit (M-Lead) Receive (E-Lead)
On-Hook Off-Hook On-Hook Off-Hook
Type I Standard ground battery open
1
/battery ground
Type I Compatible open
1
/battery ground ground open
1
/battery
Type V open
1
/battery ground open ground
Type V Reversed ground open ground open