Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-128Add PRI Over PACCON to R6si
5
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 6 Maintenance for R6r
.
Contact INADS to Enable Customer Options and
Verify Alarm Origination
1. Be sure the system is part of the existing INADS database by calling the
INADS Database Administrator at the Technical Service Center (TSC).
Verify that INADS can dial into the system and that the system can dial out
to INADS.
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and enables the customer
options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has
purchased a services contract, the system cannot report any alarm
to the TSC automatically, causing the TSC to be unable to fulfill the
services contract.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press
Enter to verify that the system is in the “active/standby” mode.
2. Enter save translation and press
Enter. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
3. If the system contains a TN750 Announcement circuit pack, enter list
configuration software-version and press
Enter.
If Page 2 of this form shows that recorded announcements were saved,
these announcements can be restored using restore announcements
and press
Enter.
NOTE:
TN750C contains non-volatile RAM and does not require the “restore
announcements” command.
4. Update backup tape, if required.
Reboot the System
1. Behind the PPN, set the circuit breaker to ON.