Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Management Terminal and Activate System
Page 3-18Set System Maintenance Parameters
3
Set System Maintenance Parameters
If the system does not contain a TN778 Packet Control circuit pack, skip this
section and proceed to ‘‘
Administer System Configurations (Release 6r)’’.
1. Verify the terminal screen displays: Command:
2. Type change system-parameters maintenance and press
Enter. Verify
the screen displayed is similar to Screen 3-5
. The screen shows default
values and the cursor is positioned on Product Identification: line.
Screen 3-5. Typical System-Parameters Maintenance Screen
!
CAUTION:
To prevent unnecessary trouble tickets, do not enable the system
alarms (Alarm Origination feature) until all installation and
administration procedures are completed.
3. Move the cursor by pressing Ta b to move down the screen from field to
field and enter
y in the Packet Bus Activated? field to indicate a
TN778 circuit pack is installed. This is the only field needing change on
this screen to turn the red LEDs off.
4. Press
Enter when the information is correct.