Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Management Terminal and Activate System
Page 3-30Save Translations
3
Save Translations
Save Translations (Release 6si)
For standard reliability systems, 1 translation card plus 1 backup is required. For
high or critical reliability systems, 2 translation cards plus 2 backups are
required.
!
CAUTION:
Do not attempt to save translations on the orange-labeled, 10 MB memory
card. Use the white translation card.
1. At the Command: prompt, enter save translation and press Enter.
2. After several minutes, the Save Translation screen appears.
3. Verify a “ 0” (zero) displays in the Error Code column for each SPE. A “0
indicates that the save translation completed successfully. If not, the save
translation did not complete. Record the “error code number” and the
“error message” and notify your Lucent Technologies representative.
4. Remove the original card from the TN777B and replace with backup card.
5. Repeat Steps 1 through 4 for the backup card(s).
6. Remove the backup card and replace it with the original card.
7. Label the backup card with the date and time of the backup and store it in
a secure place.
Save Translations (Release 6r)
To copy the current system translations onto both disks:
1. Enter the save translation command.
2. Verify the save completes to both disks and returns a result code of “0
(zero).
Add Translations
1. Refer to
DEFINITY Enterprise Communications Server Release 6
Administration and Feature Description
, to add new terminals.
2. Enter the save translation command to merge these translations with the
contents of disk or flash memory.
3. If a standard reliability Release 6r system is installed, enter the backup
disk incremental command. If a high or critical reliability Release 6r
system is installed, enter the backup disk incremental both command.