Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-113Add Packet Bus to R6si
5
Add Packet Bus to R6si
Standard Reliability R6si System
Disable Alarm Origination
1. Enter change system-parameters maintenance and press Enter.
2. Set the Alarm Origination Activated field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
3. For some releases of software, disable Cleared Alarm
Notification and Restart Notification before submitting the
form.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press
Enter to verify that the system is in the “active/standby” mode.
2. Enter save translation and press
Enter. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
Install Circuit Packs
1. Power down the PPN, then EPN1, and then EPN2 as required.
2. At the PPN, install the appropriate circuit packs. See Table 5-20
.
1. Quantity of this pack should equal the number of EPNs.
2. Optional for digital trunk testing.
Table 5-20. Circuit Pack Locations for Packet Bus in R5si+m PPN
Circuit Pack Carrier Quantity Slot
TN778 Control Carrier A 1 PACKET CONT
TN570 Control Carrier A 1 or 2
1
EXPN INTFC/1 and /2
TN771C Control Carrier A 1
2
Any Available Port Slot