Install and Wire Telephones and Other Equipment
Page 5-116Add Packet Bus to R6si
5
.
Power Up System
1. Power up the system.
2. Enter change system-parameters maintenance and press
Enter. Use this
form to enable the packet bus.
3. Perform tests.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 6 Maintenance for R6r
.
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that INADS
can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database Administrator
enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has purchased a
services contract, the system cannot report any alarm to the TSC
automatically, causing the TSC to be unable to fulfill the services contract.
1. Quantity of this pack should equal the number of EPNs.
2. Required for critical reliability EPN. Optional for digital trunk testing in high reliability
EPN.
Table 5-23. Circuit-Pack Locations for Packet Bus in Each EPN
Circuit Pack Carrier Quantity Slot
TN570 Expansion Control
Carrier A
1 or 2
1
EXPN INTFC/01 and /02
Port Carrier B 1 or 2 EXPN INTFC/02 and /03
TN771C Expansion Control
Carrier A
1
2
Any Available Port Slot