Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-134CAMA/E911 Installation
5
Hardware Setup
1. Insert the TN429C CO circuit pack in any available port slot.
2. Wire the TN429C to the MDF (the trunk from the CO). Refer to the pinouts
in Table 5-34
.
Administration Setup
1. At the prompt, type add trunk next and press Enter.
TN780 Tone Clock Not Affected Used in the
U.S. (infre-
quently) for
stratum 3 clock-
ing and used in
many other
countries
Tone clock only,
no TTR/CPTR
functionality. Typ-
ically found with
TN748 circuit
packs in the U.S.
Use TN7744DV2
instead of TN748
with CAMA.
TN2182
TN2182B
Tone Clock /
Call Classifier -
Detector
Compatible Used globally Tone clock plus 8
GPTR/call classi-
fication ports. Use
TN2182B if
CAMA feature is
to be supported.
Table 5-24. Compatibility Tone Clock, TTR/CPTR, and GPTR Circuit Packs
Continued
Circuit
Pack Description
Compatibility
with CAMA
Trunks in
Same PN Application Notes
Continued on next page