Install and Wire Telephones and Other Equipment
Page 5-129Add PRI Over PACCON to R6si
5
2. The system performs a reset level 4 reboot, loading translations from the
translation card. Rebooting requires 8 to 11 minutes.
3. Login at the login: prompt on the management terminal, and set the
time to ensure that the system is booted properly.
4. Enter list configuration software-version and press
Enter to compare the
version number of the software program (displayed on the terminal) with
the TN790 version number (written on a label on the TN790’s faceplate). If
the version numbers are not the same, change the version number on the
TN790 label so that they agree.
NOTE:
Certain forms have changed for Release 6. Upgraded translations
may appear on a different form, fields may shift within a form, or the
names assigned to particular fields may change. Refer to
DEFINITY
Enterprise Communications Server Release 6 Transition Reference
,
and
DEFINITY Enterprise Communications Server Release 6
Administration and Feature Description
, and make the necessary
changes.
Enable Customer Options
1. Enter change system-parameters customer-options and press Enter.
2. Use these forms to verify the customer options are properly set.
NOTE:
If the customer was using Supplementary Services Protocol “b” or
“d” on an ISDN-PRI trunk group before the upgrade, set the Basic
Call Setup field to y.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 6 Maintenance for R6r
.