Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-125Add PRI Over PACCON to R6si
5
Service Interruption
1. Since the addition of PRI Over PACCON requires a service interruption,
notify the customer in advance as to when the addition will take place.
Disable Alarm Origination
1. Enter change system-parameters maintenance and press Enter.
2. Set the Alarm Origination Activated field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
3. For some releases of software, disable Cleared Alarm Notification
and Restart Notification before submitting the form.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press
Enter to verify that the system is in the “active/standby” mode.
2. Enter save translation and press
Enter. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
3. If the system contains a TN750 Announcement circuit pack, enter display
announcements and press
Enter.
If administered recorded announcements are listed, enter list
configuration software-version press
Enter. To save the announcements,
enter save announcements and press
Enter.
Power Down System
If the packet bus is being added:
1. At the PPN, set the main circuit breaker to OFF.
2. At each EPN, set the main circuit breaker to OFF.
Add Circuit Packs
1. To control every ISDN-PRI link in the system, a TN778 Packet Control
circuit pack and TN464 ISDN-PRI circuit packs are required.