Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Test Telephones and Other Equipment
Page 6-4Test Music-on-Hold
6
Test Music-on-Hold
Verify music is provided to a held party during any hold interval.
Test Emergency Transfer
Put system in emergency transfer mode and make call using emergency transfer
telephone. There may be up to 4 Emergency Transfer switches depending on the
system configuration. The switch is located on the Processor circuit pack(s) in
the Processor Port Network (PPN) Control Carrier.
Test Remote Access Interface
Test the communication link between the system and the remote interface
(formerly INADS) and verify the alarm notification process. Make a remote test
from the remote interface to the DEFINITY System and a local test from the
DEFINITY System to the remote interface.
In some countries, this remote access interface is not allowed. Contact your
Lucent Technologies representative.
Remote Test
1. Call outside personnel who will be accessing the system remotely to
perform administration, maintenance, and testing.
2. Ask remote personnel to call system and login and display System
Parameters Maintenance screen. The login must be successful.
NOTE:
Product Identification on the System Parameters screen must match
the Product Identification administered by the local technician.
3. Have the remote personnel enter the test inads-link command, terminate
the login, and disconnect.
4. Have the remote personnel check the appropriate trouble ticket. The
trouble ticket should show “INADS,n,MINOR” in the description field to
indicate a minor off-board alarm was reported to the remote personnel.
There may be more text in the description field if other resolved alarms
were reported.
5. Have the remote personnel make second call and login to the system and
check the error log to verify no problems. See
DEFINITY Enterprise
Communications Server Release 6 Maintenance for R6r
, for error log and
error code information.
6. Have the remote access personnel terminate logoff and disconnect.