Install and Wire Telephones and Other Equipment
Page 5-123Add ISDN—BRI
5
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 6 Maintenance for R6r
.
Contact INADS to Enable Customer Options and
Verify Alarm Origination
1. Be sure the system is part of the existing INADS database by calling the
INADS Database Administrator at the Technical Service Center (TSC).
Verify that INADS can dial into the system and that the system can dial out
to INADS.
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has
purchased a services contract, the system cannot report any alarm
to the TSC automatically, causing the TSC to be unable to fulfill the
services contract.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press
Enter to verify that the system is in the “active/standby” mode.
2. Enter save translation and press
Enter. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
3. If the system contains a TN750/B Announcement circuit pack, enter list
configuration software-version and press
Enter. If Page 2 of this form
shows that recorded announcements were saved, these announcements
can be restored using restore announcements and press
Enter.
4. Update backup tape, if required.