Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-118Add CallVisor ASAI
5
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press
Enter to verify that the system is in the “active/standby” mode.
2. Enter save translation and press
Enter. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
3. If the system contains a TN750 Announcement circuit pack, enter display
announcements and press
Enter.
If administered recorded announcements are listed, enter list
configuration software-version and press
Enter. Check Page 2 of this
form to see when the announcements were last saved. To save the
announcements, enter save announcements and press
Enter.
Power Down System
If the packet bus is being added:
1. At the PPN, set the main circuit breaker to OFF.
2. At each EPN, set the main circuit breaker to OFF.
Add Circuit Packs
1. Determine port assignment of circuit packs to be added.
2. Install the appropriate circuit pack in assigned cabinet slot (as required).
For example:
The TN748C or TN744 Call Classifier circuit pack is required. The TN744 is
required for those customers who desire switch call classification.
A vacant port is required on a TN556 ISDN—BRI circuit pack.
3. A Packet Bus is required with CallVisor ASAI. If the system is not equipped
with a Packet Bus, see “Add Packet Bus to R6si
” earlier in this chapter.
Port Number 3 B 02 01
Cabinet
(Port Network)
Carrier Slot Circuit