Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-85Add CO, FX, WATS, and PCOL
5
Add CO, FX, WATS, and PCOL
Requirements
Each Central Office (CO), Foreign Exchange (FX), Wide Area
Telecommunications Service (WATS), or Personal Central Office Line (PCOL)
trunk is connected to 1 port of either an 8-port TN747 or to 1 of an assortment of
non-United States CO Trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from Trunk Group form. For
example:
2. See ‘‘
Off-Premises Station Wiring’’ on page 5-30 and install a TN747 or a
non-United States CO trunk circuit pack in the assigned carrier slot (if an
additional circuit pack is required).
3. Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in
DEFINITY Enterprise Communications Server Release 6 Administration
and Feature Description
.
Port Number 3 A 07 01
Cabinet
(Port Network)
Carrier Slot Circuit