Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Management Terminal and Activate System
Page 3-29Reboot High Reliability System
3
Reboot High Reliability System
1. Enter reset system 4.
2. When the login: prompt appears, login as craft.
3. About eight minutes after booting and at the Command: prompt, enter the
status spe command.
4. Verify that handshake, shadowing, and refreshed are all shown to
be either yes or on.
Enable Duplication and Boot Critical Reliability
System (Release 6r)
1. Enter change system-parameters duplication.
2. Make sure duplication of both SPE and PNC are enabled on the screen
that follows the command. Confirm that a y is contained in both fields.
3. Enter save translation.
4. Enter reset system 4 to reboot the system.
5. When login: appears on the screen, login as craft.
6. About eight minutes after booting the system and at the Command:
prompt, enter the status spe command.
7. Verify that handshake, shadowing, and refreshed are all shown to
be either yes or on.
Administer Attendant Console
1. Enter display system-parameters country-options and press Enter to
verify the system’s companding mode for its local stations is set to the
desired value (usually, A-Law for Europe and mu-Law for North America
and Japan).
2. If necessary, enter change terminal-parameters 603/302B1 and press
Enter to change the default system-level parameters and audio levels for
these terminals.
NOTE:
For information about changing the default parameters and audio
levels, refer to
DEFINITY Application Notes
available through the
International Technical Assistance Center (ITAC).
3. Administer other forms listed under Attendant Console in
DEFINITY
Enterprise Communications Server Release 6 Administration and Feature
Description
.