Install Management Terminal and Activate System
Page 3-13Set Country Options
3
5. If all red LEDs do not go off, reseat (unplug and reinsert) any
purple
-labeled circuit packs displaying red LEDs.
!
CAUTION:
To avoid a disk crash, never reset the DEFINITY AUDIX System
without first shutting it down. Shut down the DEFINITY AUDIX System
(and allow the disk to completely spin down) before unplugging the
assembly. See ‘‘
DEFINITY AUDIX Power Procedures’’ on page 3-32
for the proper procedures.
6. If the red LEDs still do not go off, refer to
DEFINITY Enterprise
Communications Server Release 6 Maintenance for R6r
, or to
DEFINITY
Enterprise Communications Server Release 6 Maintenance for R6vs/si
.
NOTE:
Ignore the red alarm indication LED on the TN767 or TN464 DS1
circuit pack until after the DS1 circuit pack is administered. Alarms
will appear in the Alarm Log when power is applied to the system
before all equipment connecting to port circuit packs is installed.
Normally, some alarms will be logged when power is applied to the
system, but should be resolved quickly. If no equipment is
connected to the port circuit packs, alarms associated with these
ports can take up to four hours to log, but will clear automatically
after all equipment is installed and operating correctly.
Table 3-1. Country Codes
Country Code Country Code
USA 1 France 12
Australia 2 Germany 13
Japan 3 Czechoslovakia 14
Italy 4 Russia 15
The Netherlands 5 Argentina 16
Singapore 6 Greece 17
Mexico 7 China 18
Belgium 8 Hong Kong 19
Saudi Arabia 9 Thailand 20
United Kingdom 10 Macedonia 21
Spain 11