Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-63Multi-point Adapters
5
Basic Multipoint Installation Distances
Figure 5-28 provides cabling information for fan-out of ISDN-BRI multi-point
installations. The terminating resistor is generally located in the satellite closet. All
distances assume 24 AWG (#5) (0.26 mm
2
) D-Inside Wire (DIW).
Figure 5-28. Basic Multi-point with 1 Work Location
Figure Notes
1. S-Interface Source (TN556)
2. Terminating Resistor
3. Satellite Closet
4. Maximum Distance from S-Interface
Source to Work Location (1600 Feet)
(488 m)
5. Maximum Distance From Satellite
Closet to Work Location (250 Feet)
(76 m)
6. System Cabinet
7. Terminating Endpoint 1
8. Terminating Endpoint 2
9. Work Location
10. Maximum Distance from
Information Outlet to Terminating
Endpoint (33 Feet) (10 m)
11. Information Outlet (Bridged Tap)
2
3
8
9
7
1
10
11
11
5
4
6
inst_dis CJL 030796