Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-6Analog Tie Trunk Example
5
Analog Tie Trunk Example
This example shows how to connect analog tie trunk wiring from one DEFINITY
System to another DEFINITY System.
Figure 5-5. Analog Tie Trunk Wiring
1. Set the option switches on the port circuit pack (TN760) as described in
Appendix B, ‘‘
Option Switch Settings’’.
2. Install cross-connect jumpers to connect the named pins from the tie trunk
circuit pack to the appropriate leads on the external tie trunk. Names of
the tie trunk leads must be determined from the manufacturer or supplier
of the external trunk circuit. The example in Figure 5-5
shows a DEFINITY
System tie trunk connected to a DEFINITY System tie trunk.
3. Administer on the Trunk Group screen of the management terminal. See
DEFINITY Enterprise Communications Server Release 6 Administration
and Feature Description
for more details.
Figure Notes
1. External Trunk or Adapter 2. TN760 Tie Trunk Circuit Pack (Position 1C05)
tie_wire RBP 071796
1
27
26
29
4
30
5
2
28
3
31
6
T. 1
R.1
T1.1
R1.1
E.1
M.1
T.2
R.2
T1.2
R1.2
E.2
M.2