DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Management Terminal and Activate System
Page 3-27Administer Fiber Links (Release 6r Only)
3
6. The Fiber Link Administration form appears. On Page 1, enter the Board
Location: for ENDPOINT-1 and ENDPOINT-2. This is the cabinet,
carrier, and slot that identifies the physical location of an SNI or EI circuit
pack that is the first endpoint of the fiber link. Repeat for the remaining
endpoints.
7. The Board Type field is display only and shows the type of circuit pack in
Endpoint-1.
8. In the DS1CONV Board Location: field, enter the cabinet, carrier, and
slot that identifies the physical location of DS1 Converter circuit pack in
the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along
with Endpoint-2’s duplicate make up the duplicate fiber link called the
B-PNC link.
9. The DS1CONV Board Type: field is display only and shows the type of
DS1 Converter circuit pack in Endpoint-1. The circuit pack type in
Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the same.
10. In the Is one endpoint remoted via a DS1 Converter
Complex? field, enter y to specify that a DS1 Converter complex is used
to remote 1 endpoint. If a y is entered, administer the A-PNC DS1
Converter Board Location on Page 1. The A-PNC DS1 Converter Board
Type displays. Administer the A-PNC DS1 Converter (DS1CONV)
Attributes on Page 2 of this form.
11. On Page 2 of the form, enter the DS1 Converter Facilities information. In
the Facility Installed? field, enter y for all installed facilities (A, B,
C, and D).
12. In the Bit Rate
: field, enter 1.544 for T1 operation or 2.048 for E1
operation.
NOTE:
One bit rate applies for all facilities within the same DS1 Converter
complex. The Bit Rate: field displays only under Facility A.
13. Enter the idle code in the Idle Code MSB (1) . . . . LSB (8):
field. The default value is 11101000. It is recommended that the default
value be used unless it becomes absolutely necessary to change it. The
“MSB” means Most Significant Bit, the “LSB” means Least Significant Bit.
14. In the Line Coding: field, enter the line coding information. This
information should match the line coding of the facility. For T1, example
line coding is b8zs. For E1, example line coding is hdb3. Scroll to Page 3
and modify the fields as needed for the B-PNC.
NOTE:
If this data is not correct, wideband errors (such as multimedia call
handling) may occur.
15. For T1 sites, refer to ‘‘
T1 Installations Only’’. For E1 sites, refer to ‘‘E1
Installations Only’’.