Lucent Technologies Release 6 Security Camera User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Test the System
Page 4-7Test Duplicated Switch Processing Element Interchange
4
Test Duplicated Switch Processing
Element Interchange
For high and critical reliability systems only.
1. Verify the screen displays: Command:
2. Type status cabinet <1-44> and press
Enter.
3. Verify the screen displays test results similar to Screen 4-6
.
Screen 4-6. Example System Status Report for All Cabinets
4. Note the MODE of SPE 1A and 1B.
5. Type refresh spe and press
Enter.
Command successfully completed should be displayed.
6. Type reset system interchange and press
Enter. This causes the terminal
to log off.
7. Log in as craft again. Remember to use the new password established for
craft.
8. Note the MODE for SPE 1A and 1B should have changed from that noted
in Step 4.