Cisco Systems OL-25712-04 Security Camera User Manual


 
Port Channel—All links from an IOM to a fabric interconnect are grouped in a port channel.
Global—The chassis inherits this configuration from the chassis discovery policy. This is the default
value.
Step 6
Click Save Changes.
Configuring the Rack Server Discovery Policy
Rack Server Discovery Policy
The rack server discovery policy determines how the system reacts when you add a new rack-mount server.
Cisco UCS Manager uses the settings in the rack server discovery policy to determine whether any data on
the hard disks are scrubbed and whether server discovery occurs immediately or needs to wait for explicit
user acknowledgement.
Cisco UCS Manager cannot discover any rack-mount server that has not been correctly cabled and connected
to the fabric interconnects. For information about how to integrate a supported Cisco UCS rack-mount server
with Cisco UCS Manager, see the hardware installation guide for that server.
Configuring the Rack Server Discovery Policy
Procedure
Step 1
In the Navigation pane, click the Equipment tab.
Step 2
On the Equipment tab, click the Equipment node.
Step 3
In the Work pane, click the Policies tab.
Step 4
Click the Global Policies subtab.
Step 5
In the Rack Server Discovery Policy area, complete the following fields:
DescriptionName
The way the system reacts when you add a new rack-mount server. This
can be one of the following:
Immediate—The system attempts to discover new servers
automatically
User Acknowledged—The system waits until the user tells it to
search for new servers
Action field
The scrub policy to run on a newly discovered server if that server meets
the criteria in the selected server pool policy qualification.
Scrub Policy drop-down list
Cisco UCS Manager GUI Configuration Guide, Release 2.0
244 OL-25712-04
Configuring the Rack Server Discovery Policy