Procedure
Step 1
In the Navigation pane, click the SAN tab.
Step 2
In the SAN tab, expand SAN > SAN Cloud.
Step 3
Right-click SAN Pin Groups and select Create SAN Pin Group.
Step 4
Enter a unique name and description for the pin group.
Step 5
To pin traffic for fabric interconnect A, do the following in the Targets area:
a) Check the Fabric A check box.
b) Click the drop-down arrow on the Interface field and navigate through the tree-style browser to select
the uplink Fibre Channel port you want to associate with the pin group.
Step 6
To pin traffic for fabric interconnect B, do the following in the Targets area:
a) Check the Fabric B check box.
b) Click the drop-down arrow on the Interface field and navigate through the tree-style browser to select
the uplink Fibre Channel port you want to associate with the pin group.
Step 7
Click OK.
What to Do Next
Include the pin group in a vHBA template.
Deleting a SAN Pin Group
Procedure
Step 1
In the Navigation pane, click the SAN tab.
Step 2
In the SAN tab, expand SAN > SAN Cloud > SAN Pin Groups.
Step 3
Right-click the SAN pin group you want to delete and select Delete.
Step 4
If the Cisco UCS Manager GUI displays a confirmation dialog box, click Yes.
Cisco UCS Manager GUI Configuration Guide, Release 2.0
344 OL-25712-04
Deleting a SAN Pin Group