Cisco Systems OL-25712-04 Security Camera User Manual


 
Server Power State After
Communication Is Disrupted
Current Server Power StateDesired Power State in Service
Profile
Powered On
Running servers are not
shut down regardless of
the desired power state in
the service profile.
Note
Powered OnDown
Reacknowledging a Rack-Mount Server
Perform the following procedure if you need to have Cisco UCS Manager rediscover the server and all
endpoints in the server. For example, you can use this procedure if a server is stuck in an unexpected state,
such as the discovery state.
Procedure
Step 1
In the Navigation pane, click the Equipment tab.
Step 2
On the Equipment tab, expand Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to acknowledge.
Step 4
In the Work pane, click the General tab.
Step 5
In the Actions area, click Server Maintenance.
Step 6
In the Maintenance dialog box, do the following:
a) Click Re-acknowledge.
b) Click OK.
Cisco UCS Manager disconnects the server and then builds the connections between the server and the fabric
interconnect or fabric interconnects in the system. The acknowledgment may take several minutes to complete.
After the server has been acknowledged, the Overall Status field on the General tab displays an OK status.
Decommissioning a Rack-Mount Server
Procedure
Step 1
In the Navigation pane, click the Equipment tab.
Step 2
On the Equipment tab, expand Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to decommission.
Step 4
In the Work pane, click the General tab.
Step 5
In the Actions area, click Server Maintenance.
Step 6
In the Maintenance dialog box, do the following:
Cisco UCS Manager GUI Configuration Guide, Release 2.0
OL-25712-04 605
Reacknowledging a Rack-Mount Server