Renumbering a Chassis
You cannot renumber a blade server through Cisco UCS Manager. The ID assigned to a blade server is
determined by its physical slot in the chassis. To renumber a blade server, you must physically move the
server to a different slot in the chassis.
Note
Before You Begin
If you are swapping IDs between chassis, you must first decommission both chassis and then wait for the
chassis decommission FSM to complete before proceeding with the renumbering steps.
Procedure
Step 1
In the Navigation pane, click the Equipment tab.
Step 2
On the Equipment tab, expand Equipment > Chassis.
Step 3
Verify that the Chassis node does not include the following:
The chassis you want to renumber
A chassis with the number you want to use
If either of these chassis are listed in the Chassis node, decommission those chassis. You must wait until the
decommission FSM is complete and the chassis are not listed in the Chassis node before continuing. This
might take several minutes.
Step 4
On the Equipment tab, click the Chassis node.
Step 5
In the Work pane, click the Decommissioned tab.
Step 6
For the chassis that you want to renumber, do the following:
a) Right-click the chassis and choose Re-commission Chassis.
b) In the Chassis ID field of the Re-commission Chassis dialog box, type or use the arrows to choose the
ID that you want to assign to the chassis
c) Click OK
Step 7
If the Cisco UCS Manager GUI displays a confirmation dialog box, click Yes.
Cisco UCS Manager GUI Configuration Guide, Release 2.0
OL-25712-04 581
Renumbering a Chassis