Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
1015Trunk Group
17
Outgoing Seizure Response (sec)
This timer is sent to the TN438B, TN439, TN447, TN458, TN464B (or later),
TN465B (or later), TN767, TN2140, TN2147, TN2184, TN2199, and TN2242
circuit packs.
Programmed Dial Pause (msec)
This timer is administrable for all outgoing and two-way trunk groups. This timer
works with the TN464B (or later), TN767, TN458, TN2140, and TN2242 tie
circuit packs. All CO circuit packs that accept administrable timers accept this
timer.
Disconnect Signal Error (sec)
This field appears for ground-start trunk groups.
Flash Length (msec)
This timer is sent to TN436B, TN459B, TN464C (or later), TN465B (or later),
(TN753 if Country is
23), TN2146, TN2147, TN2184, and TN2199 circuit
boards.
Valid entries Usage
1
to 255 in
increments of 1
Enter the maximum interval that the switch should wait after
sending a seizure signal to receive seizure acknowledgment
from the far-end. If the acknowledgment is not received in this
time, a seizure failure response is uplinked. For Brazil pulsed
E&M signaling, use
255.
Valid entries Usage
100
to 25500 in
increments of
100
Set the exact duration of pauses used during abbreviated
dialing, ARS outpulsing, and terminal dialing operations.
Valid entries Usage
1
to 255 in
increments of 1
Enter the maximum interval that the switch will wait to receive
a disconnect signal from the far-end switch after the local party
(a phone or tie trunk) goes on-hook. If the timer expires, the
system assumes a disconnect failure and take appropriate
action such as creating an error message.
Valid entries Usage
10
to 2550 in
increments of
10
Enter the duration of a flash signal generated toward the central
office.