Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Managing group communication
376Setting up voice paging over loudspeakers
14
Instructions
As an example, let’s set up voice paging for an office with 5 zones. We’ll allow
users to page all 5 zones at once, and we’ll assign a class of restriction of 1 to all
zones.
1. Type
change paging loudspeaker and press RETURN.
The Loudspeaker Paging
screen appears.
2. In the Voice Paging Timeout field, type
30.
This field sets the maximum number of seconds a page can last. In our
example, the paging party will be disconnected after 30 seconds.
3. In the Port field for Zone 1, type
01C0501.
Use this field to assign a port on an auxiliary trunk circuit pack to this zone.
4. In the Voice Paging — TAC field type
301.
Use this field to assign the trunk access code users dial to page this zone.
You cannot assign the same trunk access code to more than one zone.
5. In the Voice Paging — COR field type
1.
Use this field to assign a class of restriction to this zone. You can assign
different classes of restriction to different zones.
6. On the Zone 1 row, type
Reception area in the Location field.
Give each zone a descriptive name so you can easily remember the
corresponding physical location.
LOUDSPEAKER PAGING
CDR? y
Voice Paging Timeout (sec): 30
Code Calling Playing Cycles:
PAGING PORT ASSIGNMENTS
Voice Paging Code Calling
Zone Port TAC COR TN TAC COR TN Location:
1: 01C0501 301 1 1 1 Reception area
2: 01C0502 302 1 1 1 Shipping & receiving
3: 01C0503 303 1 1 1 Staff offices
4: 01C0504 304 1 1 1 Management suite
5: 01C0601 305 1 1 1 Breakroom
6: 1 1
7: 1 1
8: 1 1
9: 1 1
ALL: 310 1 1 1