Screen reference
568Data modules
17
ITC
(Information Transfer Capability) Used with 7500, Announcement, Netcon,
Processor/Trunk, and Processor Interface Data Modules. Appears only when the
Comm Type field is
56k-data or 64k-data. Indicates type of transmission
facilities to be used for ISDN calls originated from this endpoint. Does not display
for voice-only or BRI stations.
TN
Establish Connection
Used with X.25, Point-to-Point, and Processor Interface data modules. Refer to
DEFINITY ECS Administration for Network Connectivity for more information.
Connected to
Used with Data Line and Processor/Trunk (
pdm selection) Data Module. This
field shows to what the Asynchronous Data Unit (ADU) is connected.
Connected Data Module
Used with X.25 and Processor Interface data modules. Refer to DEFINITY ECS
Administration for Network Connectivity for more information.
Valid entries Usage
restricted
Either restricted or unrestricted transmission facilities are used
to complete the call. A restricted facility is a transmission
facility that enforces 1’s density digital transmission (that is, a
sequence of 8 digital zeros are converted to a sequence of 7
zeros and a digital 1).
unrestricted
Only unrestricted transmission facilities are used to complete
the call. An unrestricted facility is a transmission facility that
does not enforce 1’s density digital transmission (that is, digital
information is sent exactly as is).
Valid entries Usage
1
- 20 Enter the Tenant Partition number.
Valid entries Usage
dte
Data Terminal Equipment. Used with Data Line and
Processor/Trunk Data Modules.
isn
Information Systems Network. Used with Data Line and
Processor/Trunk Data Modules.