NOTE:
Use the add station command if this is a new DCP extension. Use
the
change station command for an existing DCP extension and
ignore steps 2 and 3.)
2. In the Port field, type
x for virtual phone or enter the port number if there is
hardware.
3. In the Security Code field, enter the password for this remote user, such as
1234321.
This password can be up to 7 digits in length.
4. In the IP Softphone field, type
y.
5. Move to the Service Link Mode field, type
as-needed.
Set this field to
permanent only for extremely busy remote phone users,
such as call center agents.
6. Press
ENTER to save your work.
Now you can install and configure the software on the user’s PC. In this example,
the user will login by entering their DCP extension (3010) and password
(1234321).
Tip:
You can use
list multimedia ip-softphones
to display the available
extensions permitted for IP Softphones and the associated media complex
extension (the H.323 extension), and the port, where assigned.
Related topics
Refer to the ‘‘
DEFINITY Internet Protocol (IP) Softphones’’ on page 1119 for
descriptions of the DEFINITY IP Softphone configurations.
Refer to the online help and to IP Softphone Overview and Troubleshooting for
customer information on DEFINITY IP Softphone applications. This document is
a Portable Document Format (PDF) document that is located in the Overview
Document folder on the DEFINITY IP Softphone CD.
Also refer to Getting Started, located on the DEFINITY IP Softphone CD for
more information on how to install and configure the IP Softphone software.