DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Managing multimedia calling
240Multimedia Call Handling
9
Administration commands
System-Parameters Customer-Options form:
To enable the MMCH release 6.3 feature, you must change the System-Parameters
Customer-Options form. There are two MMCH related fields on page 2 of this
form.
The “Multimedia Call Handling (Basic)” field must be set to ‘y’ to allow
MMCH Basic mode operation.
The “Multimedia Call Handling (Enhanced)” field must be set to ‘y’ to
allow MMCH Enhanced mode operations.
System-Parameters Features form:
The default bandwidth for MMCH calls is defined on the System-Parameters
Features form shown below.
NOTE:
Originating a multimedia call with the mm-call button will originate a call
according to the Default Multimedia Parameters selected on the System
Parameters Features form.
This default parameter will be either 2x56 or 2x64.
The bearer capability of the multimedia calls will either be 56K or
64K and the bandwidth will be 2B channels.
Data module screen
The H.320 DVC system should contain a BRI interface. You must connect this
BRI interface to a port on a TN556 BRI circuit pack and administer it as a BRI
data module.
You may administer the data endpoint type as 7500 (recommended) or
WCBRI.
The fields for multimedia are the same on either screen.
The administration for a Basic mode and an Enhanced mode data module
are exactly the same.