Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Enhancing system security
331Setting up authorization codes
11
12. In the Feature Button Assignments section, type one of the following:
asvn-halt — The Authorization Code Security Violation
Notification call is activated when an authorization code security
violation is detected. This applies only if you are using authorization
codes.
lsvn-halt — The Login Security Violation Notification call is
activated a referral call when a login security violation is detected.
rsvn-halt — The Remote Access Barrier Code Security Violation
Notification call is activated as a call referral. This applies only if
you are using Remote Access barrier codes.
ssvn-halt — The Station Code Security Violation Notification call
is activated when a station code security violation is detected. This
applies only if you are using station codes.
NOTE:
Any of the above 4 security violations will cause the system to place
a notification call to the designated phone. The call continues to ring
until answered. To stop notification of any further violations, press
the button associated with the type of violation.
13. Press
ENTER to save your changes.
Setting up authorization codes
Authorization codes provide the means for extending control of system users’
calling privileges. They extend calling-privilege control and provide an extra level
of security for remote-access callers.
NOTE:
To maintain system security, Lucent recommends you use
authorization codes.
Refer to BCS Products Security Handbook for more information.
Before you start
On the System Parameters Customer-Options
screen, verify the Authorization
Codes field is
y. If not, contact your Lucent representative. This field turns on the
feature and permits you to selectively specify levels of calling privileges that
override in-place restrictions.