DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Features and technical reference
1165Automatic Number Identification
20
If your switch contains a voice-synthesis board, ACA referral calls are
accompanied by an audible message identifying the type of ACA infraction
encountered. The message is “Automatic circuit assurance <long> or
<short> holding time threshold has been exceeded for trunk group <#>
member number <#>.”
Voice Message Retrieval
If you use Voice Message Retrieval, you can assign a nondisplay telephone
as a referral destination.
Wideband Switching
ACA treats wideband-trunk calls as a single-trunk call and therefore
triggers a single referral call. The call information shows the lowest
B-channel trunk member associated with the wideband channel.
Automatic Number Identification
Inband Automatic Number Identification
Your switch uses Inband Automatic Number Identification (ANI) to interpret
calling party information, such as a calling party number or a billing number.
Inband signaling is when information such as the address digits for the called
party is delivered over the same trunk circuit used for the voice or data connection.
(Out-of-band or ISDN signaling is when signaling information passes through a
different signaling path than the one used for the voice or data connection.)
When a call is made from 555-3800 to your display phone at 81120, and the
Incoming Tone (DTMF) ANI field is set to
*ANI*DNIS*, your trunk group receives
*5553800*81120*. If the field is set to
ANI*DNIS*, your trunk group receives
5553800*81120*. In both cases, Call From 555-3800 appears on your display.
If you do not use Inband ANI, the incoming trunk group name appears on your
phone display.
Related topics
Refer to ‘‘
Trunk Group’’ on page 967 for information about setting Inband ANI
on the trunk group form.