Screen reference
733IP Trunk Configuration Manager
17
Routing Info -
Terminating Dial
Plan
Entry Type: Sets whether or not incoming calls are accepted.
The default value is Accept. If you set this to Reject, then
incoming calls are not accepted.
Search Digits: See the Dial/Routing Plan Worksheets.
Replace Digits: See the Dial/Routing Plan Worksheets
Line Number: In non-DCS configurations, enter Any.
For DCS networks, specify the trunk group number for calls that
terminate at this switch. The trunk group number must match the
trunk group number at the originating switch. .
Routing Info -
Access Control
In Use For:
Gateways: Use the access control entry being created when
gateways (such as other DEFINITY ECS servers) attempt to
make calls to this IP trunk server.
Client: Use the access control entry being created when clients
(such as NetMeeting™ PCs) attempt to make calls to this switch.
Gateway/Client: Specifies that the entry being created will be
used for both switches and clients when they attempt to make
calls to this switch.
IP Address: Specifies the IP address of the remote system (or
subnet) that is being given access to this switch.
Address Bits to Match: Specifies the number of bits (starting
with the left-most or high-order bit) that are used to control
access to this DEFINITY ECS application. A value of 32 limits
access to the individual IP address entered. A value of 24 limits
access to the 255 IP addresses in a class C IP address (in other
words, a subnet). The range of values is 0 - 32. The default value
is 32. When the Access Control list is empty, any IP address can
send calls (access) to the local DEFINITY ECS application.
Once a single entry exists in the list,
only IP addresses explicitly
specified in the list can access the local application.
Add Allows you to add the names of DEFINITY ECS applications
connected to your network. Allows you to add originating and
terminating dial/routing plan information and access control
information.
Parameter Description
Continued on next page