Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Collecting billing information
446Receiving call-charge information
16
More information
You can also establish a class of restriction with Forced Entry of Account Codes
set to
y, and assign this COR to trunks or other facilities that you want to restrict.
With this method, all users with this COR must enter account codes before
making any outgoing trunk calls. See ‘‘
Class of Restriction’’ on page 520 for
more information.
Receiving call-charge information
DEFINITY ECS provides two ways to receive information from the public
network about the cost of calls. Note that this service is not offered by the public
network in some countries, including the US.
Advice of Charge (for ISDN trunks) collects charge information from the
public network for each outgoing call. Charge advice is a number
representing the cost of a call; it may be recorded as either a charging or
currency unit.
Periodic Pulse Metering (for non-ISDN trunks) Periodic Pulse Metering
(PPM) accumulates pulses transmitted from the public network at periodic
intervals during an outgoing trunk call. At the end of the call, the number of
pulses collected is the basis for determining charges.
Before you start
You need to request either AOC or PPM service from your network provider. In
some areas, your choice may be limited. Your Lucent Technologies representative
can help you determine the type of service you need.
NOTE:
This service is not offered by the public network in some countries,
including the US.
Collecting call charge information over ISDN
In this example, we administer the system to provide Advice of Charge over an
existing ISDN trunk group, at the end of a call. This information will appear on
CDR reports.
1. Type
change trunk-group 2.
The ISDN trunk group screen appears with existing administration for this
ISDN trunk group.