DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
929System Parameters Customer-Options
17
G3 Version
Identifies the version of DEFINITY ECS being used.
Maximum Ports
Number of ports active, per contract.
Location
Indicates the location of this switch. 1 indicates Canada or the United States. 2
indicates any other location, and allows the use of International Consolidation
circuit packs and telephones.
Maximum XMOBILE Stations
Specifies the maximum number of allowable XMOBILE stations. In general, each
XMOBILE station is assigned to a wireless handset.
Maximum H.323 Trunks
Appears when the H.323 Trunks field is
y. Specifies the maximum number of
H.323 trunks that may be administered.
Maximum H.323 Stations
Appears when the IP Stations field is
y. Specifies the maximum number of H.323
stations that may be administered.
Valid entries Usage
0
- 36065 (G3r)
0 - 3500
(G3vs/si/csi)
Shows the maximum number of XMOBILE stations. Each
XMOBILE station counts as a station and a port in terms of
system configuration.
Valid entries Usage
0
- 1000 (G3r)
0 - 300
(G3si/csi)
Shows the maximum number of H.323 trunks. The combined
total of H.323 stations, IP SoftPhones, and H.323 trunks cannot
exceed 1000 for G3r or 300 for G3si/csi.
Valid entries Usage
0
- 1000 (G3r)
0 - 300
(G3si/csi)
Shows the maximum number of H.323 stations. The combined
total of H.323 stations, IP SoftPhones, and H.323 trunks cannot