DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
566Data modules
17
Port
Used with 7500, Data Line, Ethernet, Processor/Trunk, PPP, System Port, X.25,
and World Class BRI Data Modules. Specifies a port location to which the data
module is connected.
NOTE:
You can enter X in the Port field to indicate that there is no hardware
associated with the port assignment (also known as administration
without hardware). These stations are referred to as “phantom
stations.” If this data module is designated as a secondary data
module (Secondary data module set to
y) X cannot be entered into
this field. The port of a primary data module cannot be changed to X
if a secondary data module is administered.
COR
Enter the desired class of restriction.
Multimedia
Used with the 7500 and World Class BRI Data Modules. Appears only if, on the
System-Parameters Customer-Options screen, the MM field is
y.
Destination Number
Used with X.25 and Processor Interface data modules. Refer to DEFINITY ECS
Administration for Network Connectivity for more information.
Characters Meaning Value
1-2 Cabinet Number 01 through 44 (G3r configurations)
01 through 03 (G3si configurations)
3 Carrier A through E
4-5 Slot Number 0 through 20
6-7 Circuit Number 01 through 04 (x.25 circuit pack)
01 through 31 (G3si configurations)
Valid entries Usage
0
- 95 Select the allowed restriction.
Valid entries Usage
y/n
Enter y to make this data module part of a multimedia
complex.