Screen reference
728IP Trunk Configuration Manager
17
Telephony Advanced dialog box
Use the Telephony Advanced dialog box to adjust additional telephony
parameters.
The Telephony Advanced dialog box contains the following parameters:
Maximum Digits to
Be Collected
Allows you to set the maximum number of digits that the IP trunk
application will accept from the switch for an outgoing call.
If this value is less than the number of digits actually forwarded by
the PBX, the calls will not go through.
!
CAUTION:
Set this field no higher than the maximum length of the digit
string the switch sends. Otherwise, the IP trunk application
waits several seconds for additional digits and users experience
delays.
Valid values:
0 to 30
Advanced Displays the Telephony Advanced dialog box, where you can set
additional telephony parameters.
Parameters Description
Ring Count
10 to 32767
Allows you to set the number of rings before the DEFINITY ECS
application hangs up because of a No Answer message.
First Digit Time Out
2000 to 600,000
Allows you to set the first digit time-out interval in milliseconds for
the DEFINITY ECS application.
Inter Digit Time
Out
2000 to 600,000
Allows you to set the inter digit time-out interval in milliseconds,
which sets the time of arrival of subsequent dialed digits from the
user.
Wink Wait Time
1000 to 600,000
Allows you to set the maximum time to wait for the far end to wink
for an outgoing call. Set to 0 if no wink is expected.
Continued on next page
Parameter Description
Continued on next page