Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
1017Trunk Group
17
Normal Outgoing Seize Send (msec)
This field appears only if the Trunk Signaling Type field is
dis and the trunk group
Direction field is
two-way or outgoing. Only TN2140 ports receive this timer.
Release Ack Send (msec)
After your switch receives a forward release signal, it must send a forward release
acknowledgment signal. This field appears only if the Trunk Signaling Type field
is
dis and the trunk group Direction field is incoming or two-way. Only TN2140
ports receive this timer.
Seize Ack Delay (msec)
This field appears only if the Trunk Signaling Type field is dis and the trunk group
Direction field is
incoming or two-way. Only TN2140 ports receive this timer.
Answer Send (msec)
This field appears only if the Trunk Signaling Type field is
dis and the trunk
group Direction field is
incoming or two-way. Only TN2140 and TN2199 ports
receive this timer.
Valid entries Usage
10
to 990 in
increments of
10
Enter the duration of the signal your switch sends for an
outgoing seizure.
Valid entries Usage
500
to 1200 in
increments of
100
Enter the duration of the signal your switch sends for a forward
release acknowledgment.
Valid entries Usage
40
to 120 in
increments of
10
Enter the maximum interval your switch will wait after receipt
of an incoming seizure to send seizure acknowledgment.
Valid entries Usage
10
to 2550 in
increments of 10
Enter the duration of the answer signal pulse.