DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
615DS1 Circuit Pack
17
Network Management Protocol
This field appears only if the Framing Mode field is
esf.
Send ANSI-T1.403 One-Second Performance
Reports
This field selects whether your DS1 circuit pack will send error reports to the
far-end switch. These reports are useful for network management, and are sent at
1-second intervals when enabled. This field appears only if the Framing Mode
field is
esf. It is used only with circuit packs that have an integrated channel
service unit (CSU).
Far-end CSU Address
This field, which, appears only if the Framing Mode field is
esf.
Transmit LBO (Transmit Line Build-Out)
This field reduces the outgoing signal strength by a fixed amount. The appropriate
level of loss depends on the distance between your switch (measured by cable
length from the smart jack) and the nearest repeater. Where another switch is at
the end of the circuit, as in campus environments, use the cable length between the
2 switches to select the appropriate setting from the table below. This field appears
if the Near-end CSU Type field is
integrated.
Valid entries Usage
tabs
The entry in this field, used only with circuit packs that have
an integrated channel service unit (CSU), allows the data link
to be remotely monitored.
Valid entries Usage
y/n
Enter n. Consult your Lucent representative if you think you
may want to use these reports.
Valid entries Usage
a
Enter b. This field administers the transmit direction address
used for the
ESF data link command with both integrated and
external channel service units (CSU).
b
Valid entries Usage
0db
For distances of 2,001–3,000 feet
-7.5db
For distances of 1,001–2,000
-15db
For distances of 0–1,000 feet
-22.5db
For mid-span repeaters