DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
565Data modules
17
Physical Channel
Used with Netcon and Processor Interface Data Modules. The Physical Channel
number is referred to on associated system forms as the Interface Link number
.
Board
Used with Announcement Data Modules. Enter the five character announcement
circuit pack number that identifies the physical circuit pack to which the
announcement module is connected. You can enter
X in this field to indicate that
there is no hardware associated with this port assignment.
The five character announcement board number is comprised of:
Valid entries Usage
01 - 08
For Processor Interface Data Modules, enter the 2-digit circuit
number of the Processor Interface port. A multi-carrier cabinet
system supports the use of two Processor Interface circuit packs, the
first circuit pack (mounted in Control Carrier A) supports physical
channels or links 01 through 04; the second (mounted in Control
Carrier A) supports physical channels or links 05 through 08. A
single-carrier cabinet system supports one Processor Interface circuit
pack and physical channels or links 01 through 04 only.
01 - 04
For G3csi configurations. For Netcon Data Modules, enter a
netcon data channel.
01-08
For G3si configurations. For Netcon Data Modules, enter a
netcon data channel.
Characters Meaning Value
1-2 Cabinet Number 01 through 44 (G3r
configurations)
01 through 03 (G3si
configurations)
3 Carrier A through E
4-5 Slot Number or X 1 through 20