Screen reference
897Station
17
ITC (Information Transfer Capability)
Indicates the type of transmission facilities to be used for ISDN calls originated
from this endpoint. The field does not display for voice-only or BRI stations.
Lock Messages
Loss Group
This field determines which administered 2-party row in the loss plan applies to
each station. Does not appear for stations that do not use loss (for example,
x-mobile stations and MASI terminals).
LWC Activation
Valid entries Usage
restricted
If you set to restricted, either restricted or unrestricted
transmission facilities are used to complete the call. A restricted
facility is a transmission facility that enforces 1’s density digital
transmission (that is, a sequence of 8 digital zeros are converted
to a sequence of 7 zeros and a digital 1).
unrestricted
If you set to unrestricted, only unrestricted transmission
facilities are used to complete the call. An unrestricted facility
is a transmission facility that does not enforce 1’s density
digital transmission (that is, digital information is sent exactly
as is).
Valid entries Usage
y/n
Enter y to restrict other users from reading or canceling the
voice messages or retrieving messages via Voice Message
Retrieval.
Valid entries Usage
1
-17 Shows the index into the loss plan and tone plans.
Valid entries Usage
y/n
Enter y to allow internal telephone users to leave short LWC
messages for this extension.
If the system has hospitality, enter
y for guest-room telephones
if the extension designated to receive failed wakeup messages
should receive LWC messages that indicate the wakeup calls
failed.
Enter
y if LWC Reception is audix.