Lucent Technologies 8.2 Security Camera User Manual


  Open as PDF
of 1707
 
DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Features and technical reference
1496Station Hunting
20
Call Vectoring
You cannot assign a Vector Directory Number as a hunt-to station.
If a
route-to command’s with cov y directs a call to a busy station, the call
follows the station’s hunt-to chain and not its coverage path. Refer to
DEFINITY ECS Call Vectoring/EAS Guide or DEFINITY BCS and
Guestworks Call Vectoring Guide for more information.
Call Waiting/Attendant Call Waiting
Station Hunting has precedence over Call Waiting.
If a called extension has Call Waiting active, and the extension is already
busy on a call, the system hunts the station-hunting chain. If the system
cannot terminate the call to a member of the chain, then the call waits at the
called extension.
If the system finds Call Waiting active at an extension in a station-hunting
chain, it considers the extension busy and bypasses it.
Class of Restriction
The system checks the COR of the called extension; it does not check the
COR of the hunt-to stations in the chain.
Distributed Communications System
Station Hunting is not a DCS feature. All members of a station-hunting
chain must be on the same switch.
Do Not Disturb
When a phone has Do Not Disturb activated, a call to that phone goes to
intercept treatment and not to station hunting.
Extension Number Portability
You cannot assign a remote ENP extension as a hunt-to station.
Hunting/Hunting Group
You cannot assign a direct departmental calling or Uniform Call
Distribution extension as a hunt-to station.
Intercom Call
The system denies Station Hunting for intercom calls to a busy extension.
Leave Word Calling
If a caller initiates Leave Word Calling (LWC), the LWC message is left at
the called extension even if the system uses Station Hunting in an attempt
to complete the call.
Multimedia
Calls to multimedia endpoints must convert to voice before station hunting.