DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Features and technical reference
1348Hospitality features
20
Interactions
Coverage
XDID ports perform hunt-to before coverage. After hunting, coverage
criteria for these calls is based upon the Direct Inward Dialing (DID), but
the coverage points are based upon the hunted-to phone (room).
Coverage
Do not assign a COS with Client Room enabled for the XDID station types.
Automatic Wakeup
Automatic Wakeup allows attendants, front desk users, and guests to request an
automatic wakeup call at a later time.
If the Dual Wakeup field on the Hospitality
screen is y, each extension is allowed
two wakeup call requests within one 24-hour time period. If the Room Activated
Wakeup with Tones field is
y, wakeup calls can be activated via tones that prompt
users for the time they want to be called.
Detailed description
Wakeup requests may be placed from 5 minutes to 23 hours and 55 minutes in
advance of a wakeup call.
Depending on how automatic wakeup is administered, when a user answers a
wakeup call, the system can provide:
a recorded announcement
a speech-synthesis announcement
music
silence
All wakeup times entered into the system round to the nearest five minutes. For
example, a requested time of 6:58 am stores in the system as 7:00 am. The switch
bases time-validity checks on the rounded figure.
Wakeup calls are placed within two and one-half minutes of the requested time,
and never reroute, forward, or go to coverage. Before placing the wakeup call, the
system overrides Do Not Disturb for the extension.