DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506
Issue 1
April 2000
Features and technical reference
1192Busy Verification
20
Considerations
■ A busy verification cannot be made to an analog extension that is waiting to
be answered at another extension. A call must be answered before it can be
verified.
■ If your country requires a tone other than 440 Hz, use the Intrusion feature
rather than Verify to verify telephones.
■ The system does not provide bridging when you verify UCD and DDC
groups or RLTs.
■ You cannot make outgoing test calls on DID trunks.
■ You can verify an extension that is administered without hardware
(X-ported). In this case, the system generates reorder tone.
Table 16. Verification of a Trunk
Trunk Status System Response Result
The trunk is idle
and incoming.
■ The system generates
confirmation tone.
■ Verification is complete.
■ Anyone can use the trunk.
The trunk is idle
and outgoing.
■ The system generates dial
tone.
■ Verification is complete.
■ Anyone can use the trunk.
The trunk is busy
with an active call.
■ The system bridges the Verify
originator onto the call.
■ The system generates a
warning tone to all active
parties and repeats the tone
every 15 seconds while the
Verify originator remains
bridged onto the call.
■ Verification is complete.
■ The trunk is in use.
The trunk is out of
service.
■ The system generates reorder
tone.
■ Verification is denied.